Product Description:

Apera TN500 uses a tungsten filament lamp as the light source and 90° scattering method, which is compliant with the U.S EPA 180.1 method for the determination of turbidity in drinking, ground, surface, and saline waters, domestic and industrial wastes. The instrument is designed for water quality professionals, offering long-term reliability in high-accuracy turbidity measurement with an intuitive operation system, simple calibration, and GLP data management.

Product Specifications:

SpecificationDescription
Measurement Method90° scattering measurement, U.S EPA180.1 compliant
Light SourceTungsten filament lamp
Measuring Range0 to 1000 NTU (FNU), automatic range switch 0.01 to 19.99 NTU(FNU) 20.0 to 99.9 NTU(FNU) 100 to 1000 NTU(FNU)
Accuracy≤ ±2% of reading+ stray light
Repeatability≤ ± 1% of reading or 0.02 NTU(FNU) (the greater of the two)
Resolution0.01/0.1/1 NTU (FNU)
Stray Light≤0.02 NTU (FNU)
Calibration StandardAMCO Polymer or Formazin Solution:0, 20, 100, 400 and 800NTU (FNU)
DetectorSilicon photovoltaic
Measuring ModeNormal measurement and TruRead measurement
Data Storage200 groups
Data OutputUSB to PC
USB to PCCalibration date and time
DisplayTFT color screen
Sample VialΦ25×60 mm,high borosilicate glass with lid
Sample Vial Volume18 ml
Power supply3.7V Rechargeable lithium battery
Working ConditionTemperature: 0 to 50°C(32°F to 122°F); Relative humidity: 0 to 90% at 30°C, 0 to 80%at 40°C, 0 to 70% at 50°C, no condensation
Instrument sealing gradeIP67
CertificatesISO9001:2015 and CE
Limited Warranty2 years
Dimension and WeightMeter: (90×203×80) mm/385g Test Kit: (310×295×110) mm/1.5kg

 


Premium-quality tungsten filament lamp light source

Compliant with the U.S EPA 180.1 method for the determination of turbidity in drinking, ground, surface, and saline waters, domestic and industrial wastes. The lamp is replaceable.


TruRead™ measurement mode

Automatically takes multiple consecutive readings, and calculate the average, minimum and maximum value, as well as displaying each set of data in a brief test report. TruRead is a much better way to determine the true turbidity of your samples, rather than relying on just one reading. It's especially suitable for sample solutions with rapid settling and continuous measurement changes.


EPA approved AMCO® standards

The kit comes with AMCO® high-molecular polymer turbidity standard solutions (0, 20, 100, 400, 800 NTU), which are EPA approved primary standards that are safe, non-toxic and disposable, and have a guaranteed one-year shelf life. It is NIST traceable to particle size/distribution and optical density, and its inherent stability means it does not settle from suspension. Store the standards at room temperature. They must not be frozen.


Intuitive Operation System

The meter is equipped with a large TFT color screen with plain language and graphic navigation, supporting English, Spanish, and Chinese. Intelligent functions such as automatic calibration, real-time clock display, calibration date check, auto. power off, and low battery reminder are built-in to ensure ease of use.


GLP Data Management

200 sets of data storage with USB data output to PC (Windows-based only)



Zero turbidity error reminder

The zero-point calibration and zero-point error reminder functions ensure the high accuracy for low-turbidity (<1 NTU) sample testing


Rechargeable battery

3.7V rechargeable lithium battery can supply power for over 20 hours of continuous measurement. The battery life is 5 times longer compared with other products in the market.

 

Additional Resources and Information:

 T500 Manual 

TN500 Portable White Light Turbidity Meter with Data Logger, EPA Compliant

      Qty:

      1,180.00 1,180.00 1180.0 USD

      1,180.00

      Option not available

      Add to Cart
      Credit Cards

      TN500 Portable White Light Turbidity Meter with Data Logger, EPA Compliant Accessories:

      TN400-S2 Sample Vials Set
      Cat. No.:
      TN400-S2
      Description:


      23.00 23.0 USD

      View Details
      TN400-S3 Silicone Oil
      Cat. No.:
      TN400-S3
      Description:


      12.00 12.0 USD

      View Details
      T500-1 Polymer AMCO Turbidity Standard Calibration Solution Kit (20/100/400/800NTU) for TN500 and TN420
      Cat. No.:
      TN500-S1
      Description:


      130.00 130.0 USD

      View Details
      T500-2 AMCO 0 NTU Standard Calibration Solution 100ml Refill
      Cat. No.:
      TN500-S2
      Description:


      75.00 75.0 USD

      View Details
      T500-3 Sample Vials (Pack of 6)
      Cat. No.:
      TN500-S3
      Description:


      46.00 46.0 USD

      View Details
      T500-4 Rechargeable Lithium Battery
      Cat. No.:
      TN500-S4
      Description:


      25.00 25.0 USD

      View Details

      View our 2023
      Product Catalog

      Get our complete and
      latest product portfolio
      for free.

      Download Scilogex
      Literature

      Find a collection of product manuals and brochure PDFs available for download.

      Earn Rewards

      Scilogex members earn points
      whenever they log in and use their
      account. Cash in your points to enjoy
      exclusive deals and discounts on our
      lab equipment and supplies.